KMID : 0213520080220040236
Korean Journal of Ophthalmology
2008 Volume.22 No. 4 p.236 ~ p.241
Comparison of OCT and HRT Findings Among Normal, Normal Tension Glaucoma, and High Tension Glaucoma
Shin In-Ha

Hong Sa-Min
Kim Chan-Yun
Kang Sung-Yong
Seong Gong-Je
Kim Seung-Kab
Tak Ma-Kyung
Abstract
Purpose: To evaluate the relationship between optic disc and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina topography (HRT) in normal, normal tension glaucoma (NTG), and high tension glaucoma (HTG).

Methods: Normal, NTG and HTG subjects who met inclusion and exclusion criteria were evaluated retrospectively. One hundred seventy eyes of 170 patients (30 normal, 40 NTG, and 100 HTG) were enrolled. Complete ophthalmologic examination, HRT, OCT, and automated perimetry were evaluated.

Results: Disc area, cup area and cup/disc area ratio measured with HRT were significantly different between NTG and HTG (all p<0.05). Mean RNFL thickness measured by OCT with ascanning diameter of 3.4 mm was larger in NTG than HTG (84.97¡¾24.20 ¥ìm vs. 73.53¡¾27.17 ¥ìm, p=0.037). Four quadrant RNFL thickness measurements were not significantly different between NTG and HTG (all p>0.05). Mean deviation and corrected pattern standard deviation measured by automated perimetry was significantly correlated with mean and inferior RNFL thickness in both NTG and HTG (Pearson¡¯s r, p<0.05). Mean RNFL thickness/disc area ratio was significantly larger in HTG than NTG (35.21¡¾18.92 vs. 31.30¡¾10.91, p=0.004).

Conclusions: These findings suggest that optic disc and RNFL damage pattern in NTG may be different from those of HTG.
KEYWORD
High tension glaucoma, Normal tension glaucoma, Retinal nerve fiber layer