Abstract
|
|
|
The contraceptive implant is an effective and well-established method of contraception. A 43-year-old woman presented with paresthesia and weakness of left hand. Symptoms began 3 weeks ago, immediately after removal of a contraceptive device in the left arm. A nerve conduction study showed proximal median neuropathy, and ultrasonography revealed focal
swelling of the median nerve at the level of removal. Although nerve damage is a rare complication, special care should be taken to avoid nerve injury during removal procedure.
|
|
KEYWORD
|
|
Median neuropathy, Contraceptive devices, Ultrasonography
|
|