Background and Objectives£ºEarly color M-mode Doppler flow propagation (Vp) has been used to distinguish pseudonormal from normal diastolic filling patterns. However, the role of other indices, including the late diastolic propagation velocity (Ap) and time delay of mitral flow propagation (VpTD and ApTD), is not clear.

Subjects and Methods£ºDoppler echocardiographic examinations were performed in 89 patients (60.6¡¾9.9 years, male 59.6%), with an ejection fraction ¡Ã40%, who were admitted for diagnostic coronary angiography. The clinical diagnoses on admission were stable angina (41.6%), unstable angina (30.3%), old myocardial infarction (24.7%) and atypical chest pain (3.3%). The diastolic filling patterns, as confirmed by mitral inflow and pulmonary venous flow, were compared with the Ap, VpTD and ApTD indices using color M-mode Doppler echocardiography.

Results£ºThe age, left ventricular ejection fraction, left ventricular end diastolic and end systolic dimensions, the left atrial size, and the E¡¯and A¡¯velocities of the mitral annulus tissue Doppler were significantly different between patients with normal and abnormal diastolic filling patterns. In patients with normal filling, impaired relaxation and pseudonormalized filling patterns, the VpTD were 63.1¡¾14.9, 85.2¡¾25.5 and 107.8¡¾36.8 ms (p<0.001), the E/Vp were 1.3¡¾0.4, 1.6¡¾0.6 and 3.1¡¾0.7 (p<0.001), and the E/VpTD were 1.2¡¾0.5, 0.7¡¾0.2 and 0.9¡¾0.4 (p<0.001), respectively. The Ap and ApTD showed significant differences between patients with normal and pseudonormalized filling patterns (Ap 58.3¡¾23.5 vs. 36.2¡¾15.1, p=0.000; ApTD 47.1¡¾19.5 vs. 66.7¡¾22.2, p=0.001). The PVa duration, an index that depends on the left ventricular end-diastolic pressure, was the most important independent predictor for ApTD from a multiple regression analysis (R2=71.4%).

Conclusion£ºThe color M-mode Doppler indices, Ap, VpTD and ApTD, are new diagnostic parameters for diastolic dysfunction.