Very Late Stent Thrombosis in Coronary Bare-Metal Stent Implantation: A Case Report
|
|
Cho Yoon-Sung
Jung Hyun-Gwang Kim Tae-Woo Kim Kang-Min Chang Jae-Hoon Rho Dong-Hyun Lee Chang-Hun Lee Joon-Sang Ahn Byung-Jae Jeong Joon-Hoon
|
|
Abstract
|
|
|
Stent thrombosis is generally a fatal complication after percutaneous coronary intervention. Despite the incidence of stent thrombosis has reduced with improved techniques and drugs, stent thrombosis persists at a rate of 0.5-2% in elective cases, and up to 6% in patients with acute coronary syndromes. It almost always causes acute myocardial infarction or sudden cardiac death. While very late stent thrombosis, occurring beyond 1 year, is not uncommon with the use of drug-eluting stents, it is distinctly unusual with the use of bare-metal stents. We report a case of very late thrombosis of a bare-metal stent occurring 880 days after coronary stent implantation.
|
|
KEYWORD
|
|
Coronary thrombosis, Stents
|
|