KMID : 0368120090390070270
|
|
Korean Circulation Journal 2009 Volume.39 No. 7 p.270 ~ p.274
|
|
Midterm Results of Aortic Arch Replacement in a Stanford Type A Aortic Dissection With an Intimal Tear in the Aortic Arch
|
|
Cho Seong-Ho
Sung Ki-Ick Park Kay-Hyun Yang Ji-Hyuk Kim Wook-Sung Jun Tae-Gook Lee Young-Tak Park Pyo-Won
|
|
Abstract
|
|
|
Background and Objectives : Stanford type A aortic dissection is a potentially catastrophic event that requires surgical repair, on an emergency basis. The extent of arch repair that should be carried out during emergency surgery of this type is controversial. This study was designed to evaluate the results of arch replacement carried out during acute type A dissection.
Subjects and Method : 28 patients with Stanford type A dissection and who underwent arch replacement between 1995 and 2006 were reviewed.
Results: Hospital mortality was 3.6% (1 patient), and transient neurocognitive dysfunction was observed in 5 patients. During the follow-up period (mean 26¡¾20 months; range 1 to 66 months), 3 patients underwent reoperation due to descending thoracic or abdominal aortic aneurysm. There was no late death. Follow up computed tomography was performed in 15 patients and false lumen disappeared totally or partially in 10 patients (66.7%).
Conclusion: Arch replacement for acute Stanford type A dissection may decrease the risk of late complications related to false lumen and lead to an excellent midterm survival rate.
|
|
KEYWORD
|
|
Aortic dissection
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|