Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0368120100400080405
Korean Circulation Journal
2010 Volume.40 No. 8 p.405 ~ p.409
A Novel Technique for Retrieval of a Drug-Eluting Stent After Catheter Break and Stent Loss
Wani Sunil P.

Rha Seung-Woon
Oh Dong-Joo
Shin Seung-Yong
Kim Jin-Won
Park Ji-Young
Choi Cheol-Ung
Kim Eung-Ju
Seo Hong-Seog

Moon Ji-Mi
Lim Hong-Euy
Kim Ji-Bak
Park Chang-Gyu
Kanhaiya L Poddar
Wang Lin
Sureshkumar Ramasamy
Choi Un-Jung
Abstract
Break of a stent delivery catheter and subsequent stent loss (SL) has been a rare event in the drug-eluting stent (DES) era. We here report a case of successful retrieval of a stent after a break if the delivery catheter and SL from a balloon catheter at a culprit lesion. We finally resolved this situation using a simple balloon technique for both the broken stent catheter inside of the guide catheter and the unexpanded stent in the culprit lesion. Thus balloons are an important weapon in our armamentarium in the cardiac catheterization laboratory for urgent retrieval of a lost stent. Their apt use definitely allowed our patient to avoid undergoing emergency cardiovascular thoracic surgery.