Fatal Delayed Coronary Artery Perforation After Coronary Stent Implantation
Kim Sang-Hoon

Moon Jae-Youn
Sung Jung-Hoon
Kim In-Jai
Lim Sang-Wook
Cha Dong-Hun
Cho Seung-Yun
Abstract
Most type I and II perforations are predominately caused by hydrophilic and stiff wires, often presented in the delayed form, and do not require pericardial drainage or surgical interventions. However, we report a type III delayed coronary artery perforation at the site of stent implantation after intervention without any evidence of immediate perforations. To the best of our knowledge, this is the first case report of angiographic documentation and treatment of delayed coronary perforation at the site of stent, presented as a cardiac arrest.
KEYWORD
Cardiac tamponade, Complications, Percutaneous transluminal coronary angioplasty, Drug-eluting stent