Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0368120160460050727
Korean Circulation Journal
2016 Volume.46 No. 5 p.727 ~ p.729
Thrombotic Occlusion of Stent Graft Limbs due to Severe Angulation of Aortic Neck in Endovascular Repair of Abdominal Aortic Aneurysm
Kim Min-Su

Kim Myeong-Gun
Kang Woong-Chol
Oh Pyung-Chun
Lee Ji-Yeon
Kang Jin-Mo
Chung Wook-Jin
Shin Eak-Kyun
Abstract
Endovascular aneurysm repair (EVAR) is a safe alternative to open surgical repair for an abdominal aortic aneurysm. However, unfavorable aortic anatomy of the aneurysm has restricted the widespread use of EVAR. Anatomic limitation is most often related to characteristics of the proximal neck anatomy. In this report, we described a patient with a severely angulated proximal neck who underwent EVAR, but required repeat intervention because of thrombotic occlusion of stent graft limbs.
KEYWORD
Abdominal aortic aneurysm, Endovascular aneurysm repair, Graft occlusion
FullTexts / Linksout information
 
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø