KMID : 0370220070510030174
|
|
Yakhak Hoeji 2007 Volume.51 No. 3 p.174 ~ p.178
|
|
Quantitative Determination of Doxifluridine and 5-FU in Monkey Serum Using LC/MS/MS
|
|
Woo Young-Ah
Kim Ghee-Hwan Kim Won Lee Jong-Hwa Jeong Eun-Ju Kim Jin-Ho Park Kui-Lea Kim Choong-Yong
|
|
Abstract
|
|
|
A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-flu-orouracil (5-FU) in monkey serum. The method has greater sensitivity and simpler process than previous published methods with good accuracy and precision. A proper liquid/liquid extraction was used to extract simultaneously doxifluridine and 5-FU which has considerable difference in the polarity. Extracts were analyzed using LC/MS/MS providing a short analysis time within 5 min. The lower limit of quantification was validated at 10.0 ng/ml of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both analytes met FDA Guidance criteria of ¡¾15% for average QC accuracy with coefficients of variation less than 15%. The method will be applicable for preclinical studies and bioequivalence studies.
|
|
KEYWORD
|
|
doxifluridine, 5-FU, LC/MS/MS, monkey, serum, simultaneous determination, validation
|
|