KMID : 0380020080230060470
|
|
Korean Journal of Biotechnology and Bioengineering 2008 Volume.23 No. 6 p.470 ~ p.473
|
|
Removal of VOC compounds in the vent of a pharmaceutical plant using a pilot-scale biofilter
|
|
|
|
Abstract
|
|
|
A pilot-plant biofilter (1750 mm W¡¿2750 mm L¡¿2000 mm H) packed with polyurethane foam (20 mm W¡¿20 mm L¡¿20 mm H) was installed in an pharmaceutical plant emitting gas streams containing n-hexane and alcohols. The biofilter was successfully operated for 74 days under highly fluctuating incoming concentrations at a residence time of 12.8-24.8 sec. Alcohols and n-hexane were removed by more than 90% from 5 and 20 days after start up, respectively. Malodor was also removed more than 95% from 20 days after start up.
|
|
KEYWORD
|
|
pilot-plant biofilter, n-hexane, alcohols, malodor
|
|