KMID : 0861420020070020161
|
|
Korean Journal of Nuclear Medicine Technology 2002 Volume.7 No. 2 p.161 ~ p.165
|
|
A Comparison between coated tube method and PEG method for quantitative determination of albumin in human urine
|
|
Seo Mi-Hye
Yoo So-Yoen Back Song-Ran Yoon Pil-Young Moon Hyung-Ho
|
|
Abstract
|
|
|
In diabetes mellitus a breakdown of the glomerular capillary blood barrier with the development of proteinuria is usually accepted as marking the onset of clinical diabetes nephrophathy. Insulin dependent diabetes mellitus characterized by persistent proteinuria, hypertension and deterioration of renal function. Clinical proteinuria becomes evident, abnormally increase rate of the urinary albumin excretion but not yet detectable with routine method of dipstick and acid precipitation test. Microalbuminuria is a condition characterized by increase urinary excretion of albumin. We compared between coated tube method and PEG method for diagnosis of microalbuminuria. The result showed that coated tube method and PEG method was highly correlated.(r=0.98)
|
|
KEYWORD
|
|
Microalbumin, Coated tube ¹ý, PEG¹ý
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|