KMID : 0880420160170030330
|
|
Korean Journal of Radiology 2016 Volume.17 No. 3 p.330 ~ p.338
|
|
Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial
|
|
Park Eun-Ah
Lee Whal Kang Doo-Kyoung Kim Sung-Jin Kim Young-Ju Kim Yoo-kyung Sung Yon-Mi Song Soon-Young Oh Yu-Whan Yong Hwan-Seok Lee Heon Jeon Eui-Yong Jin Gong-Yong Choi Byoung-Wook Choi Sang-Il
|
|
Abstract
|
|
|
Objective: This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects.
Materials and Methods: Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, left main coronary artery, and left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated.
Results: A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexol-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 ¡¾ 71.4 HU with iohexol-380 vs. 356.3 ¡¾ 61.5 HU with iohexol-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05).
Conclusion: Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.
|
|
KEYWORD
|
|
Coronary arteries, Contrast media, Contrast materials, Drug safety, Image quality enhancement
|
|
FullTexts / Linksout information
|
|
|
|