Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0880420180190061066
Korean Journal of Radiology
2018 Volume.19 No. 6 p.1066 ~ p.1076
Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases
Huh Ji-Mi

Park Ji-Suk
Kim Kyung-Won
Kim Hyoung-Jung
Lee Jong-Seok
Lee Jong-Hwa
Jeong Yoong-Ki
Shinagare Atul B.
Ramaiya Nikhil H.
Abstract
Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans.

Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations.

Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (?6.1?5.7 mm), followed by PVP (?7.9?7.1 mm) and AP (?8.5?7.4 mm) images. Intra-observer agreement showed the same trend: ?2.8?2.9 mm and ?2.9?2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, ?2.8?2.9 mm and ?3.0?3.2 mm, respectively, on PVP, and ?3.2?4.2 mm and ?3.4?3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images.

Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on precontrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.
KEYWORD
Neuroendocrine tumor, RECIST, Pre-contrast, Unenhanced, Computed tomography, Measurement, Reliability, Repeatability, Reproducibility, Observer agreement
FullTexts / Linksout information
  
Listed journal information
SCI(E) MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø