Comparison of Abbreviated MRI and Full Diagnostic MRI in Distinguishing between Benign and Malignant Lesions Detected by Breast MRI: A Multireader Study
Kim Eun-Sil

Cho Nariya
Kim Soo-Yeon
Kwon Bo-Ra
Yi Ann
Ha Su-Min
Lee Su-Hyun
Chang Jung-Min
Moon Woo-Kyung
Abstract
Objective: To compare the performance of simulated abbreviated breast MRI (AB-MRI) and full diagnostic (FD)-MRI in distinguishing between benign and malignant lesions detected by MRI and investigate the features of discrepant lesions of the two protocols.

Materials and Methods: An AB-MRI set with single first postcontrast images was retrospectively obtained from an FD-MRI cohort of 111 lesions (34 malignant, 77 benign) detected by contralateral breast MRI in 111 women (mean age, 49.8. ¡¾ 9.8; range, 28?75 years) with recently diagnosed breast cancer. Five blinded readers independently classified the likelihood of malignancy using Breast Imaging Reporting and Data System assessments. McNemar tests and area under the receiver operating characteristic curve (AUC) analyses were performed. The imaging and pathologic features of the discrepant lesions of the two protocols were analyzed.

Results: The sensitivity of AB-MRI for lesion characterization tended to be lower than that of FD-MRI for all readers (58.8?82.4% vs. 79.4?100%), although the findings of only two readers were significantly different (p < 0.05). The specificity of AB-MRI for lesion characterization was higher than that of FD-MRI for 80% of readers (39.0?74.0% vs. 19.5?45.5%, p ¡Â 0.001). The AUC of AB-MRI was comparable to that of FD-MRI for all readers (p > 0.05). Fifteen percent (5/34) of the cancers were false-negatives on AB-MRI. More suspicious margins or internal enhancement on the delayed phase images were related to the discrepancies.

Conclusion: The overall performance of AB-MRI was similar to that of FD-MRI in distinguishing between benign and malignant lesions. AB-MRI showed lower sensitivity and higher specificity than FD-MRI, as 15% of the cancers were misclassified compared to FD-MRI.
KEYWORD
Breast neoplasms, Magnetic resonance imaging, Sensitivity, Specificity, Area under the curve