Abstract
We report a rare case of delayed cement displacement after balloon kyphoplasty in patient with Kummell¡¯s desease. A 78-year-old woman with Kummell¡¯s desease at T12 level received percutaneous balloon kyphoplasty. Two months after surgery, the patient complained of progressive severe back pain. Computed tomographic scans revealed a breakdown of the anterior cortex and anterior displacement of bone cement. Although this complication is very rare, it is likely to occur in treatment of Kummell¡¯s disease accompanying anterior cortical defect.
KEYWORD
Kummell¡¯s disease, Balloon kyphoplasty, Bone cement displacement