Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1034820210170040493
Molecular & Cellular Toxicology
2021 Volume.17 No. 4 p.493 ~ p.501
The optimal standard protocols for whole-genome sequencing of antibiotic-resistant pathogenic bacteria using third-generation sequencing platforms
La Tae-Min

Kim Ji-Hoon
Kim Tae-Soo
Lee Hong-Jae
Lee Yoon-Suk
Shin Hyun-Jin
Song Yong-Jun
Ahn Gyu-Hee
Hur Won
Lee Joong-Bok
Park Seung-Yong
Choi In-Soo
Lee Sang-Won
Abstract
Background: The emergence of antibiotic-resistant bacterial pathogens in the environment has been increasing, posing a threat to public health. Next-generation sequencing technology, which is both low cost and large scale, was used to identify antibiotic-resistance genes or toxin genes in these pathogens. Short-read sequencing cannot fully reconstruct bacterial chromosomes and plasmids carrying toxin genes and antibiotic-resistance genes because of their location on the insertion sequences or repeat regions. Third-generation sequencing generated long reads that could cover the repetitive and/or insertion sequences, allowing for complete chromosome and plasmid reconstruction. However, the optimal protocols for whole-genome sequencing of antibiotic-resistance pathogenic bacteria, from DNA extraction to genome assembly, are still being researched.

Objective: To develop a pipeline of optimal methods for whole-genome sequencing of bacteria, we compared three commercial DNA extraction kits (column extraction, magnetic bead extraction, and precipitation extraction), two third-generation sequencing platforms (MinION and PacBio), and three assembly methods (flye, unicycler, and unicycler_hybrid). The assembly results were evaluated based on the number of contigs and the detection of anti-microbial-resistance genes.

Results: Magnetic bead extraction method generated longer N50 read lengths and greater read length distribution than the other two extraction methods. The Flye assembler in combination with magnetic bead extraction and MinION sequencing provided consistent successful plasmid assembly results and detected all antimicrobial-resistance gene in all datasets.

Conclusion: DNA extraction, sequencing platform, and assembly methods can all have an impact on the results of bacterial whole-genome sequencing. Our findings could be a practical protocol for researchers who use third-generation sequencing to perform bacterial whole-genome sequencing by consistently resolving small plasmids carrying antibiotic-resistance genes.
KEYWORD
Third-generation sequencing, DNA extraction, MinION, PacBio, Bacteria, Assembly
FullTexts / Linksout information
Listed journal information