Abstract
|
|
|
Negative staining has been traditionally used for exosome imaging; however, the technique is limited to surface topology only and can cause staining artifacts. Therefore, to analyze the internal structure of exosomes, we employed a method of block preparation, thin sectioning, and electron tomography. In addition, an automatic serial sectioning technique with 15-nm thickness through focused ion beam was employed to observe the three-dimensional structure of exosomes of various sizes. Cryo-transmission electron microscopy revealed the near-to-native structure of exosomes.
|
|
KEYWORD
|
|
Exosome, Electron tomography, Serial block face section through focused ion beam, Cryo-transmission electron microscopy
|
|