KMID : 1134820140430111737
|
|
Journal of the Korean Society of Food Science and Nutrition 2014 Volume.43 No. 11 p.1737 ~ p.1741
|
|
HPLC Method Validation of Naringin Determination in Goheung Yuzu Extract as a Functional Ingredient
|
|
Moon So-Hyun
Ko Eun-Young Assefa Awraris Derbie Park Se-Won
|
|
Abstract
|
|
|
An HPLC method for determination of naringin was developed to standardize it as a marker compound in Goheung yuzu extract as a functional health food. Optimum results were obtained by C-18 column chromatography using solvent mixtures (A: 0.5% acetic acid, B: acetonitrile) as the stationary phase and mobile phase. The method was fully validated and sensitive with a limit of detection (LOD) of 0.0218 mg/L and limit of quantification (LOQ) of 0.0661 mg/L. The method showed high linearity (coefficient of correlation=0.9986) and high accuracy, as recovery rates of naringin at concentrations of 1, 0.5, 0.1, 0.05 mg/mL were in the ranges of 95.74¢¦98.25%, 97.67¢¦101.01%, 97.33¢¦104.64%, and 95.53¢¦106.82%, respectively. Intra-day and inter-day variation, which are measures of method precision, were 1.39¢¦1.95% and 0.17¢¦1.49%, respectively. Therefore, the method could be used without modification for determination of naringin as a marker compound in Goheung yuzu extracts.
|
|
KEYWORD
|
|
yuzu, naringin, validation, functional food, marker compound
|
|
FullTexts / Linksout information
|
|
|
|