Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0191120130280020315
Journal of Korean Medical Science
2013 Volume.28 No. 2 p.315 ~ p.319
Use of Backboard and Deflation Improve Quality of Chest Compression When Cardiopulmonary Resuscitation Is Performed on a Typical Air Inflated Mattress Configuration
Oh Jae-Hoon

Kang Hyung-Goo
Chee Young-joon
Lim Tae-Ho
Song Yeong-tak
Cho Young-Suk
Je Sang-Mo
Abstract
No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins lying on 4 different surfaces using a visual feedback system. The surfaces were as follows: A, a bed frame; B, a deflated air mattress placed on top of a foam mattress laid on a bed frame; C, a typical air mattress configuration with an inflated air mattress placed on a foam mattress laid on a bed frame; and D, C with a backboard. Deflation of the air mattress decreased MCD significantly (B; 14.74 ¡¾ 1.36 vs C; 30.16 ¡¾ 3.96, P < 0.001). The use of a backboard also decreased MCD (C; 30.16 ¡¾ 3.96 vs D; 25.46 ¡¾ 2.89, P = 0.002). However, deflation of the air mattress decreased MCD more than use of a backboard (B; 14.74 ¡¾ 1.36 vs D; 25.46 ¡¾ 2.89, P = 0.002). The use of a both a backboard and a deflated air mattress in this configuration reduces MCD and thus helps achieve accurate CC depth during cardiopulmonary resuscitation.
KEYWORD
Backboard, Beds, Cardiopulmonary Resuscitation, Mattresses
FullTexts / Linksout information
 
Listed journal information
SCI(E) MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø