Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0352219950170010233
Kyung Hee Dental Journal
1995 Volume.17 No. 1 p.233 ~ p.253
DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS USING HOLOGRAPHIC INTERFEROMETRY



Abstract
This study investigated the time-dependent dimensional changes of elastomeric impression materials using holographic interferometry. Six commercial impression materials, Permlastic(polysulfide), Xantopren VI, (condensation silicone), low and medium viscosity of Exafine, Provil (addition silicone), and Impregum( polyether), were selected. Steel plate was used as custom tray, and each impression specimen was 20 mm in width, 15 mm in length and 3 mm in thickness. Each impression material was evaluated at 30 minutes, 1, 2 4, 6, 8 and 12 hours after setting using real-time holography.
The results were as follow
1. Xantopren VL and Permlastic showed relatively severe and continuous dimensional changes after setting. Low viscosity of Exafine, Provil, Impregum showed relatively slight dimensional changes with function of time and medium viscosity of Exafine showed almost no dimensional change from 2 hours after setting to 6 hours.
2. On initial dimensional changes within 1 hour, the amount of change in low viscosity of Exafine was the least and Xantopren VL was the largest.
3. On dimensional changes at 4 hours after setting, the amount ¢¥of change in medium viscosity of Exafine was the least and the change of Xantopren VL was the largest.
4. In overall dimensional stability during 12 hours, medium viscosity of Exafine was the most stable and Xantopren VL and Permlastic were least stable.
KEYWORD
FullTexts / Linksout information
Listed journal information