Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0355620140400050250
Journal of Korean Association of Oral and Maxillofacial Surgeons
2014 Volume.40 No. 5 p.250 ~ p.252
A simple method of intraoperative intubation tube change
Cho Jin-Yong

Kim Hyeon-Min
Ryu Jae-Young
Abstract
Nasotracheal intubation should be performed in patients with jaw fractures because maxillomandibular fixation is required. However, when there are concomitant fractures of the nose and facial bones, an intubation tube positioned at the nose makes it difficult to perform an intricate surgery. In order to overcome these problems, a variety of ways to change the position of the tube have been introduced. We describe a simple technique of switching the tube from a nasal to oral position, which was easily executed in a patient with concomitant nasal and mandibular fractures, accompanied by a literature review.
KEYWORD
Airway management, Intubation, Jaw fractures
FullTexts / Linksout information
   
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed