Mechanical Bowel Preparation for Elective Colorectal Surgery: A Prospective Randomized Study Comparing Two Liters and Four Liters of Polyethylene Glycol-Based Oral Lavage Solutions
Jo Shin-Il

Yun Seong-Hyeun
Park Jea-Kun
Kim Nam-Kyu
Sohn Seung-Kook
Min Jin-Sik
Abstract
Purpose: This study was undertaken to determine whether a mechanical bowel preparation with 2 liters polyethylene glycol solution combined with a Bisacodyl 20 mg (Group II) increases the acceptability of bowel preparation and reduces discomfort compared with 4 liters of polyethylene glycol solution (Group I).

Methods: We conducted a prospective randomized single-blinded study. Eighty patients undergoing an elective colorectal surgery in Severance hospital from April 1999 to September 1999 were included in this study. The patients¡¯ tolerance, cleansing ability and surgeon¡¯s satisfaction were assessed by a structured questionnaire. Postoperative complications were also evaluated.

Results: The patients¡¯ tolerance of the group II (2 liters polyethylene glycol solution combined with a Bisacodyl 20 mg) was better than that of the groups I (4 liters of polyethylene glycol solution). The cleaning ability and surgeon¡¯s satisfaction were not different between two groups (p=0.225, p=0.322). The incidence of postoperative complications was 2.3 percent in Group I and 2.7 percent in Group II.

Conclusion: The mechanical bowel preparation with two liters of polyethylene glycol solution with a Bisacodyl 20 mg was more comfortable to patients and equally efficient compared with the mechanical bowel preparation with the 4 liters of polyethylene glycol solution regimen before elective colorectal surgery.
KEYWORD
Mechanical bowel preparation, Colorectal surgery
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø