The Relationship Between Central Venous Pressure and Pulmonary Capillary Wedge Pressure in Patients with Aortic Stenosis
È«¿ë¿ì
¹æ¼­¿í/ÀÌÃá¼ö/À̱⹮/ÀÓÇö±³
Abstract
Background:
@EN Hemodynamic monitoring during aortic valve replacement in patients with aortic stenosis is controversial and the little prospective data on whith to base an enlightened clinical decision. The relationship between central venous pressure (CVP)
and
pulmonary capillary wedge pressure (PCWP) was examined in patients with aortic stenosis.
@ES Methods:
@EN 30 patients with aortic stenosis ho underwent aortic valve replacement wee examined.
For each patient, simultaneous measurements of CVP, pulmonary artery diastolic pressure (PADP) and PCWP were made at pre-and post-cardiopulmonary bypass. After cardiopulmonary bypass, measurement of left atrial pressure(LAP) was made.
@ES Results:
@EN The PCWP correlated well with PADP(r=0.86 p<0.01, r=0.79 p<0.01) an LAP (r=0.89 p<0.01) at the post-bypass. The CVP did not correlate with PADP(r=0.22 p>0.55, r=0.45 p>0.05), PCWP(r=0.39 p<0.0, r=0.53 p<0.01) and LAP(r=0.53 p<0.05) at pre-
and
post-bypass. The changes in CVP and PCWP also correlated poorly at pre-and post-bypass (r-0.16 p>0.05, r=0.51 p<0.05).
@ES Conclusion:
@EN This study confirmed the disparities between CVP and PCWP which were anticipated in aortic stenosis. This disparity seems due to marked differences between either compliance or function of the two ventricles. Therefore, CVP monitoring in
aortic
stenosis is limited value and may mislead in management.