Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0356920070530020250
Korean Journal of Anesthesiology
2007 Volume.53 No. 2 p.250 ~ p.253
Inadvertent Breakage of the Spinal Needle during the Obturator Nerve Block for the Transurethral Resection of Bladder Tumor
Chin Ji-Hyun

Jun In-Gu
Kim Young-Kug
Kang Keum-Nae
Hwang Gyu-Sam
Hwang Jai-Hyun
Abstract
Obturator nerve block is occasionally performed during transurethral resection of lateral bladder wall tumors to prevent the violent contraction of the adductor muscle of the thigh. Rare complications including intravascular injection of the local anesthetics and hematoma formation may occur during the obturator nerve block. We report a case of the unintentional breakage of the spinal needle during the obturator nerve block with successful removal of the broken spinal needle by an orthopedic surgeon
KEYWORD
breakage of the spinal needle, obturator nerve block, transurethral resection of bladder tumor
FullTexts / Linksout information
Listed journal information
MEDLINE ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø