Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0356920080550020241
Korean Journal of Anesthesiology
2008 Volume.55 No. 2 p.241 ~ p.243
C-arm guided placement of Fogarty embolectomy catheter for one lung ventilation in an infant
Jeon Jun-Pyo

Kwon Ou-Kyoung
Lee Jae-Min
Kim Mi-Jung
Chang Hae-Wone
Park Hyu-Jung
Abstract
We experienced one lung anesthesia using Fogarty embolectomy catheter as a bronchial blocker in an infant undergoing thoracotomy for foreign body removal. For the guidance of catheter placement in left mainstem bronchus, C-arm fluoroscopy was used. Size of catheter and its balloon was decided beforehand by measuring the diameter and length of bronchus based on the view obtained from computerized tomography. There was no accidental episode during anesthesia. C-arm fluoroscopy is safe and useful method to decide the position of Fogarty occlusion catheter in an infant. (Korean J Anesthesiol 2008; 55: 241¡­3)
KEYWORD
C-arm, Fogarty embolectomy catheter, infant, one lung ventilation
FullTexts / Linksout information