Difficult tracheostomy tube placement in an obese patient with a short neck -A case report-
|
|
Hwang Sung-Mi
Jang Ji-Su Yoo Jae-In Kwon Hyung-Ki Lee Soo-Kyung Lee Jae-Jun Lim So-Young
|
|
Abstract
|
|
|
We report a difficult case of tracheostomy in a 34-year-old obese woman with a short neck. The tracheostomy tube placement repeatedly failed because of anatomical changes due to obesity and a short neck, tracheal mucosal swelling due to prolonged intubation, and unexpected false passage; however, it was successfully performed using an endotracheal tube exchanger as a guidewire.
|
|
KEYWORD
|
|
Guidewire, Obesity, Tracheostomy
|
|