KMID : 0356920120630010072
|
|
Korean Journal of Anesthesiology 2012 Volume.63 No. 1 p.72 ~ p.75
|
|
Air embolism during off-pump coronary artery bypass graft surgery -A case report-
|
|
Chang Choo-Hoon
Shin Young-Hee Cho Hyun-Sung
|
|
Abstract
|
|
|
There have been several reports of gas embolism occurring during off-pump coronary artery bypass graft (OPCAB) surgery. However, all these cases of air embolism were associated with the repair of venous circulation, using a CO2 blower. In this report, we describe a rare case of air embolism in the coronary arteries associated with the use of a CO2 blower during OPCAB. There was no injury to the veins during OPCAB. The air embolism was treated successfully with cardiopulmonary bypass.
|
|
KEYWORD
|
|
Air embolism, Catheterization, Off-pump coronary artery bypass, Swan-Ganz
|
|