Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0357220020140030355
Journal of Korean Society Physical Therapy
2002 Volume.14 No. 3 p.355 ~ p.372
A Correction Effect of Multiaxial Lower Extremity Orthosis in Patients with Genu Valgum


Abstract
The purpose of this study was to evaluate the effect of multiaxial lower extremity orthosis on correction of genu valgum. 20 volunteers among people visited department of Rehabilitation Medicine, chungnam national university hospital, who had been diagnosed as genu valgum without other musculoskeletal problems were included. 10 individuals(mean age: 9.gyrs) who had been taken multiaxial lower extremity orthosis at least 12month were included in experimental group and the other 10 individuals(mean age: 11.7yrs) refused taking this orthosis in the control group. We measured the Q-angle & femorotibial angle using plain roentgenogram images at visiting day and repeat same test after 1year follow up. Multiaxial lower extremity orthosis consist of proximal horizontal bar with both thigh cuff, central vertical bar and distal horizontal bar with both shoes. we narrowed inter-shoes distance from start to 6th month and inter-thigh cuff distance together with above correction for next 6month in the frontal plane and from 10th month, dorsiflexed both shoes in sagittal plane. Also, we rotate the both shoes externally and retract the proximal vertical bar every month. This orthosis have to be taken at least 4 hours during sleep. The result were as follows 1. There were no statistical significant difference in each parameter between the right and left Q-angle before multiaxial lower extremity orthosis. 2. The left Q angle reduced -11^{circ} between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 3. The right Q angle reduced -13^{circ} between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 4. There were no statistical significant difference in each parameter between the right and left femorotibial angle before multiaxial lower extremity orthosis. 5. The left femorotibial angle reduced -10.1^{circ} between 1st day and after lyear follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 6. The right femorotibial angle reduced -11.2^{circ} between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001).
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed