Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0357220100220040029
Journal of Korean Society Physical Therapy
2010 Volume.22 No. 4 p.29 ~ p.33
Inter-Rater and Intra-Rater Reliability of the Modified Ashworth Scale and the Modified Tardieu Scale: A Comparison Study
Choi Yul-Jeong

Lee Choung-Ah
Shin Hwa-Kyung
Abstract
Purpose: The purpose of this study was to assess and compare the reliability of the Modified Tardieu Scale (MTS) with the Modified Ashworth Scale (MAS) in patients with hemiplegia.

Methods: Two experienced physical therapists examined twenty six patients (17 male and 9 female) with an age range of 19-83 years (mean=51.9 SD=15.2). They assessed the elbow flexor/extensor muscle spasticity in the affected side. Interand intra-rater reliability of the MAS and the MTS were calculated using kappa statistics. Intraclass correlation coefficient (ICC) was calculated to determine the inter- and intra-rater reliability of the angle of muscle reactions (R2-R1).

Results: The intra-rater reliability of the MAS (K=0.39-0.55) and MTS (K=0.33-0.55) was fair to moderate. The inter-rater reliability was significantly higheras measured with MTS (K=0.54-0.66) in comparison with MAS (K=0.52). Intra-rater reliability of R2-R1 was moderate to almost perfect (ICC=0.52-0.86), and inter-rater reliability was substantial (ICC=0.74-0.76).

Conclusion: The MTS provides higher inter-rater reliability compared with the MAS in hemiplegia patient analysis, but intra-rater reliability of both scales was not significantly different. Thus further research is needed to examine not only reliability, but also validity of these measurement systems.
KEYWORD
Plasticity, Functional MRI, Motor learning, Modified ashworth scale, Modified tardieu scale, Reliability, Spasticity
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed