Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0357520160390030323
Journal of Radiological Science and Technology
2016 Volume.39 No. 3 p.323 ~ p.328
Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures
Han Su-Cheol

Hong Dong-Hee
Abstract
The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1¡¾10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.
KEYWORD
Neuro-interventional procedures, Operator dose, Spatial dose distribution
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)