Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0358420160590040303
Korean Journal of Obstetrics and Gynecology
2016 Volume.59 No. 4 p.303 ~ p.306
Reference values for the cervical length measurement in the second trimester of pregnancy using the transvaginal ultrasound in a large Brazilian population
Alberto Borges Peixoto

Taciana Mara Rodrigues da Cunha Caldas
Ana Helena Bittencourt Alamy
Wellington P. Martins
Rafael Frederico Bruns
Edward Araujo Junior
Abstract
To establish reference values for the cervical length (CL) measurement by transvaginal ultrasound between 20 and 24+6 weeks of gestation in a large Brazilian population. A retrospective cross-sectional study was performed with 996 singleton pregnancies. The CL measurement (mm) using the transvaginal ultrasound was obtained in a sagittal view and the calipers positioned to measure the linear distance between the triangular area of echodensity at the external os and the internal os. The median¡¾standard deviation and ranges for the CL measurement (mm) was 37.0¡¾10.7 (range, 8 to 51). CL measurement did not modify significantly with gestational age. The observed percentiles for the CL measurement (mm) considering all number case were the following: 5th, 28 mm; 50th, 37 mm; and 95th, 45 mm. Reference values for the CL measurement by transvaginal ultrasound between 20 and 24+6 weeks of gestation in a large heterogeneous Brazilian population were established.
KEYWORD
Cervix uteri, Reference values, Second pregnancy trimester, Transvaginal ultrasound
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø