Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0358619920260010037
Korean Journal of Physiology
1992 Volume.26 No. 1 p.37 ~ p.44
Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier
Cho Eng-Haeng

Hah Jong-Sik
Kim, Ku-Ja
Abstract
The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 in diameter and round in shape. value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.
KEYWORD
Hemosome, Artificial red cell, Blood substitute, Encapsulation of hemoglobin
FullTexts / Linksout information
Listed journal information
´ëÇÑÀÇÇÐȸ ȸ¿ø