KMID : 0358820110380010102
|
|
Journal of Korean Society of Plastic and Reconstructive Surgeons 2011 Volume.38 No. 1 p.102 ~ p.104
|
|
Subservient Bone Reduction with Histoacryl¢ç (N-butyl-2-cyanoacrylate) in Hand Fractures: Two Cases of Report
|
|
Lee Won
Lee Sung-Hwan Oh Sang-A Kang Dong-Hee
|
|
Abstract
|
|
|
Purpose: The standard treatments of hand fractures today are fixations by K -wires, metal plates, wires and lag screws. But it is very difficult to reconstruct fractures by placing implants into small bony fragments especially in the comminuted fractures and intra-articular fractures. This paper describes a simple method of reconstruction with Histoacryl¢ç for comminuted and intra-articular fractures in hands.
Methods: 2 cases with comminuted and intra-articular fractures by crushing injury were reconstructed with Histoacryl¢ç. We performed applying Histoacryl¢ç with swab on the bone cortex carefully to avoid Histoacryl¢ç infiltrating into the medulla. We could rearrange and fixate bony fragments using only Histoacryl¢ç, in addition, metal plates, K-wires, wires, and lag screws could be used for secondary fixation if needed.
Results: Post-operative X-ray finding of 2 patients assured that the bony fragments of the hand fractures maintained their original positions. Significant displacement and deviation, infection, nonunion, and malunion during the follow-up period were not observed.
Conclusion: This study showed the possibility of using Histoacryl¢ç in addition as a simple method of fixation in the comminuted and intra-articular hand fractures.
|
|
KEYWORD
|
|
Histoacryl¢ç, N-butyl-2-cyanoacrylate
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|