Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0358920060330040606
Journal of the Korean Academy of Pedodontics
2006 Volume.33 No. 4 p.606 ~ p.614
EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN
Choi Ji-Won

Lee Nan-Young
Lee Sang-Ho
Abstract
The purpose of this study was to evaluate the polymerization contraction of composite resin(Tetric ceram {(R)}, Ivoclar Vivadent Liechtenstein) according to various liners(Tetric flow {(R)}, Ivoclar Vivadent, Liechtenstein/Ionosit {(R)}, DMG, German/ Vitrebond, {TM} 3M-ESPE, USA). The strain gauge method was used for measurement of polymerization shrinkage strain. Specimens were divided by 8 groups according to curing units and liners.
Group A, E: Tetric ceram {(R)} bulk filing, Group B, F: Tetric flow {(R)} lining, Tetric ceram {(R)} filling, Group C, G: Ionosit {(R)} lining, Tetric ceram {(R)} filling, Group D, H: Vitrebond {TM} lining, Tetric ceram {(R)} filling.
Group A, B, C and D were cured using the conventional halogen light(XL3000 {TM} 3M ESPE, USA) for 40 seconds at 400mW/cm 2. Group E, F G and H were cured using light emitted diode(LED) light(Elipar Freelight 2 {TM}, 3M-ESPE, USA) for 15 seconds at 800 mW/cm 2. Strain gauge attached to each sample was connected to a strainmeter. Measurements were recorded at each second for the total of 750 seconds including the periods of light application.
Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test.
The results of this were as follows :
1. Contraction stresses in flowable resin and glass ionomer lining group were lower than that in compomer lining group(p<0.05).
2, Contraction stresses in LED curing light groups were higher than that in halogen curing light groups, but there was no significant difference (p>0.05).
KEYWORD
Composite resin, Liner, Contraction shrinkage
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)