Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0358920080350020259
Journal of the Korean Academy of Pedodontics
2008 Volume.35 No. 2 p.259 ~ p.267
INFLUENCE OF FLOWABLE COMPOSITE LINING THICKNESS ON CERVICAL MICROLEAKAGE OF PROXIMAL BOX
Cho Yun-Jung

Kim Young-Jin
Kim Hyun-Jung
Nam Soon-Hyeun
Kim Tae-Wan
Abstract
This in vitro study aimed to investigate the influence of flowable composite lining with different thicknesses on the marginal quality. One hundred twenty cavities, each preparated with proximal boxtype( 3mm of bucco-lingual width, 2mm of mesio-distal depth and gingival margin of 1mm supra-CEJ) were randomly dived into four groups. group I : Tetric ceram filling alone(control group) group II: 0.5mm thickness Tetric flow + Tetric ceram filling group III: 1.5mm thickness Tetric flow + Tetric ceram filling group IV: 2.5mm thickness Tetric flow + Tetric ceram filling The followings are the results: 1. Group II showed significantly less microleakage compared to group I(control group)(p<0.05). 2. There was no statistically significant difference between group III, IV and group I(p>0.05). 3. Group II showed significantly less microleakage compared to group III, IV(p<0.05). 4. There was microleakage more or less in all group. It was concluded that 0.5mm flowable composite lining improved cavity adaptation and marginal sealing.
KEYWORD
Proximal box, Flowable resin, Thickness, Microleakage
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)