Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0358920180450040418
Journal of the Korean Academy of Pedodontics
2018 Volume.45 No. 4 p.418 ~ p.425
Correlation between Fluoride Release, Microhardness and Solubility of High viscosity Glass Ion
Shin Bi-Sol

Kim Jong-Soo
Yoo Seung-Hoon
Abstract
This study was to measure and compare the amount of fluoride, microhardness and solubility of high viscosity glass ionomer and resin-reinforced glass ionomer during 84 days. Fuji IX GP EXTRA, Fuji IX GP, Fuji II LC and Filtek¢â Z350XT stored in deionized water for 84 days to measure fluoride release, microhardness and solubility. As a result of measurement of fluoride release, all the glass ionomers showed the highest amount of fluoride release on day 1 and gradually decreased. Fuji IX GP EXTRA showed the highest amount of fluoride release and cumulative release. And Fuji IX GP and Fuji II LC showed no significant difference. Microhardness measurements showed that all experimental groups decreased 1 day after exposure to water. After 84 days, microhardness showed no significant difference between Fuji IX GP EXTRA and Fuji IX GP, and Fuji II LC was the lowest. In the solubility measurement, Fuji IX GP EXTRA, Fuji IX GP, and Fuji II LC increased rapidly to 21 days. After 21 days, there was no significant difference in the three groups. As a result, short term fluoride release affects solubility and microhardness, but long term fluoride release has no correlation. Through this study, the amount of fluoride, microhardness, and solubility of various glass ionomers were evaluated, and these properties could be applied clinically.
KEYWORD
Glass ionomer, Solubility, Microhardness, Fluoride
FullTexts / Linksout information
   
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)