KMID : 0359019950150040678
|
|
Korean Journal of Gastrointestinal Endoscopy 1995 Volume.15 No. 4 p.678 ~ p.685
|
|
Reproducibility of Percutaneous Sphincter of Oddi Manometry
|
|
±è¸íȯ
°í¹®¼ö/À¯º´¹«/À̹ÌÈ/ÃÖÈ£¼ø/À̼º±¸/±è¼®±Õ/¼ÛÀÏȯ/¹Ú¼±¹Ì
|
|
Abstract
|
|
|
To assess the reproducibility of Sphincter of Oddi(SO) manometry, percutaneous manometry of SO was performed repeatedly in 10 subjects with biliary diseases(9 intrahepatic stone cases and 1 bile duct cancer case). Time interval for measurement of
SO
manometry was 3 to 7(mean 5) days.
Mean manometric parameters of SO phasic contraction in the 1st and 2nd studies were not significantly different. However, as a result of manometric records, a diagnosis of dyskinesia was made in the 1st study from 4 patients(tachyoddia in 3 cases
and
increased retrograde propagation in one case). Among them, the diagnosis was reproduced in the 2nd study from 2(tachyoddia in 2 cases) out 4 patients.
In conclusion, abnormal manometric findings were poorly reproducible, Thus, more prolonged measurement of SO manometry or a dynamic test which stimuli or inhibit the SO activity may be necessary for accurate diagnosis of biliary dyskinesia and
better
reproducibility of SO manometry. (Kor J Gastrointest Endosc 15: 678~685, 1995)
|
|
KEYWORD
|
|
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|