Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0359020100400010031
Korean Journal of Gastrointestinal Endoscopy
2010 Volume.40 No. 1 p.31 ~ p.35
A Case of a Removal of Pyloric Stent That Was Partially Embeded in the Mucosa after Temporary Stenting for the Benign Pyloric Stenosis and It Was Removed Using Argon Plasma Coagulation
Oh Joo-Yeon

Park Jong-Jae
Park Ja-In
Lee Won-Woo
Roh Seung-Young
Kang Hyun-Seok
Kim Jae-Seon
Park Young-Tae
Abstract
Generally, self expandable metallic stents (SEMSs) are widely used for the treatment of malignant gastrointestinal stenosis due to their effectiveness and low complication rate. On the contraty, balloon dilatation or Bougie dilatation is commonly used for treating benign gastrointestinal stenosis as non-invasive methods. However, their such complications such as recurrence, hemorrhage and perforation are problematic when these dilation techniques are used. Temporary placement of a SEMS in a benign gastric outlet obstruction is expected to be a promising therapeutic modality despite of several major complications such as migration. Rarely, stent removal can, on rare occasions, be difficult or cause bleeding or perforation when the stent is embeded in the mucosa due to mucosal hyperplasia at the tips of the stent. We report here on a case of a stent, partially embeded in the mucosa after temporary stenting for treating a benign pyloric stenosis, which was successfully removed using argon plasma coagulation.
KEYWORD
Benign pyloric stenosis, Gastric outlet obstruction, Temporary stenting, Argon plasma coagulation, Stent removal
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø