Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0359620070190020237
Journal of Korean Knee Society
2007 Volume.19 No. 2 p.237 ~ p.243
A Short Term Follow-up of Anterior Cruciate Ligament Reconstruction using Hamstring Tendon Grafts fixed with Ligament Plate(R).
Sim Jae-Ang

Lee Beom-Koo
Kwak Ji-Hoon
Lee Kyung-Chan
Abstract
Purpose : To evaluate the clinical outcomes at a minimum of 1 year following the ACL reconstruction with use of Liga- ment Plate(R) which was invented for secure fixation of hamstring tendon graft into femoral tunnel.

Materials & Methods : Seventy-six patients who could followed up for minimum 12 months were treated with the ACL reconstruction fixed with Ligament Plate(R) using a four-stranded autologous hamstring tendon graft. For femoral fixation, we used Ligament Plate(R), and for tibial fixation, we used suture-post strengthened with cortical screw. Average follow up period was 18.6 months. Prior to surgery and at the follow-up examination, we evaluated the clinical results with Lachmann test, pivot shift test, Lysholm score and the difference of mid-thigh circumference, and KT 2000 arth- rometer was perfomed. For radiographic evaluation, we analyzed knee radiographs including anterior drawer radiographs and evaluated the degree of tunnel enlargement.

Results : Lysholm score improved from 61.6 points to 93.8 points. Lachman test revealed negative findings for sixty- three cases, and ten cases with grade 1 laxity and another three cases with grade 2 at last follow-up. Pivot shift test showed negative findings except six cases with grade 1 laxity at last follow-up. The results of KT 2000 arthrometer improved from 5.4mm difference compared with normal limb to 2.1mm respectively. The difference of mid-thigh circumference compared with normal limb showed 1.7cm. Radiographic analysis of anterior drawer view revealed 6.5 mm difference compared with normal limb preoperatively and 1.1 mm difference at last follow-up. Femoral and tibial tunnel enlarged to 2.7mm and 1.8 mm compared with immediate postoperative radiographs.

Conclusion : ACL reconstruction using hamstring tendon grafts fixed with Ligament Plate(R) could provide sufficient strength of early fixation, and then could show good clinical results. However, long term follow-up was necessary.
KEYWORD
ACL reconstruction, Hamstring tendon, Ligament Plate(R)
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø