Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0360219750160030217
Journal of the Korean Ophthalmological Society
1975 Volume.16 No. 3 p.217 ~ p.221
7 Cases of Cryopexy and Full-Thickness Scleral Buckling with Encircling Band in Retinal Detachment
À¯°æÈ­/Yoo, Kyung Wha
Á¤Çà¸í/ÀÌ¿ì½Â/Á¤¿µÅÂ/Chung, Haing Myung/Lee, Woo Seung/Chung, Young Tae
Abstract
A review of 16 patients diagnosed as having retinal detachment was presented.
These cases were patients seen in P.MC. eye clinic from Sep-73 to Feb-75.
9 of these patients did hot have operation for various reasons, but the other 7 were operated
by cryopexy, full-thickness scleral buckling with silicone materials, or encircling method with silicone band.
The results were as follows;
1) 5 among 7 patients were successful in re-attachment and improvement of visual acuity. 2) No intraocular hemorrhage, the most serious complication due to cryopexy was seen in any of these cases.
3) In one case, the encircling band and implant were removed because small pus pocket and fistula were formed on the bulbar conjunctiva 3 months postoperatively.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø