Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0360220070480010167
Journal of the Korean Ophthalmological Society
2007 Volume.48 No. 1 p.167 ~ p.171
Scleral Fixation of Foldable Intraocular Lenses Using Injector
Roh Kyu-Hwa

Park Myung-Jin
Choi Kyung-Seek
Lee Sung-Jin
Abstract
Purpose: To introduce the method of scleral fixation, using Mport(TM) (Bausch&Lomb) injector and silicone three-piece foldable IOL (Silens 6, Bausch & Lomb).

Methods: The study was conducted for five cases of aphakia requiring secondary implantation of IOL. The partial-thickness scleral flaps were made on 2 and 8 o` clock site. A double-armed 10-0 polypropylene suture and 26G needle were inserted through each sclera. Surgical and 26G needle were conjoined and passed out through 2 o` clock site sclera. The clear corneal incision was made on 10 o` clock site through which a suture was pulled out and cut. The end of suture which originated from 8 o` clock site was passed through the injector and tied to the leading haptic of IOL, then inserted. The other end of suture was tied to the following haptic and complete the insertion of IOL with forceps.

Results: Time taken for the above procedure was within 20 minutes and postoperatively induced astigmatism was less than 1.5 diopters. No specific complication was noticed.

Conclusions: This technique may be an effective and substitute procedure for that have been used for reasons of less astigmatism, and stable chamber maintenance during procedure. J Korean Ophthalmol Soc 48(1):167-171, 2007
KEYWORD
Foldable intraocular Lens, Injector, Scleral fixation
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø