KMID : 0360220090500020269
|
|
Journal of the Korean Ophthalmological Society 2009 Volume.50 No. 2 p.269 ~ p.274
|
|
10-Prism-Diopter Fixation Test for Amblyopia
|
|
Park Joo-Youn
Park Song-Hee
|
|
Abstract
|
|
|
Purpose: To evaluate the clinical usefulness of the 10-prism-diopter (PD) fixation test in the diagnosis of amblyopia.
Methods: The study comprised 132 children (42 normal, 90 amblyopes) who underwent the 10-PD fixation test and stereoacuity test. The sensitivity, specificity, false-positive and false-negative rates of the 10-PD fixation test were analyzed according to the clinical diagnosis.
Results: The 10-PD fixation test sensitivity was 86%, the specificity was 61%, the false-positive rate was 17% and the false-negative rate was 24%. Data showed agreement between the 10-PD fixation test and the stereoacuity test (¥ã=0.737, p=0.000). The results in the 10-PD base-down test and base-out test also showed agreement (¥ã=0.779, p=0.000).
Conclusions: The 10-PD fixation test is a simple and useful method in detecting amblyopia.
|
|
KEYWORD
|
|
Amblyopia, 10 prism diopter fixation test
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|