Clinical Results of Wavefront-guided LASIK
Hong Jung-Taeck

Lee Joo-Eun
Kim Jae-Yong
Kim Myoung-Joon
Tchah Hung-Won
Abstract
Purpose: To investigate and compare the clinical outcomes of wavefront-guided LASIK performed by 2 different laser platforms.

Methods:A retrospective analysis of consecutive cases of eyes that underwent wavefront-guided LASIK by using the VISX S4 CustomVue system and the Zyoptix Z100 system advanced personalized mode. All procedures were performed by one surgeon. Fifty-six eyes of 36 patients were included. Of the 56 eyes, 30 eyes underwent LASIK by using the VISX S4 CustomVue system (CustomVue group), and other 26 eyes underwent LASIK by using the Zyoptix Z100 system (APT group). Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), manifest refraction, contrast sensitivity, total high order aberration (HOA), spherical aberration (SA) and Q-value were recorded preoperatively and at 1 week, 1 and 3 months postoperatively.

Results:There was no statistically significant difference between two groups in terms of preoperative UCVA, BCVA, manifest refraction, high order aberrations, Q-value and contrast sensitivity. Induced amount of SA was significantly lower in CustomVue group than in APT group (p = 0.02).

Conclusions:Wavefront-guided LASIK performed by 2 different laser platforms caused clinically acceptable outcomes including good visual acuity and contrast sensitivity through 3 months. Furthermore, LASIK performed by VISX S4 CustomVue system caused less SA at three months after operation.
KEYWORD
High order aberration, Laser assisted in situ keratomileusis (LASIK), VISX, Wavefront, Zyoptix