KMID : 0360220120530050626
|
|
Journal of the Korean Ophthalmological Society 2012 Volume.53 No. 5 p.626 ~ p.631
|
|
The Relationship among Refractive Power, Axial Length and Choroidal Thickness Measured by SD-OCT in Myopia
|
|
Kim Keun-Ho
Kim Do-Kyun
|
|
Abstract
|
|
|
Purpose: To measure choroidal thickness in healthy myopic eyes and to evaluate the relationship among choroidal thickness and refractive power and axial length.
Methods: Eighty healthy myopic eyes were evaluated in the present study. The refractive power was measured using an automatic refractor and the axial length using A-scan. The subjects were divided into two groups based on refractive power(¡Ã-6.0 D and <-6.0 D) and axial length (¡Ã25 mm and <25 mm). The choroidal thickness was measured using spectral domain(SD) optical coherence tomography (3-dimensional [3D] OCT-2000, Software Version 6.01; Topcon Corp., Tokyo, Japan), and the statistical relationship between the two groups was analyzed.
Results: A statistically significant difference was found in choroidal thickness according to refractive power and axial length between the two groups (p < 0.001 and p < 0.05, respectively).
Conclusions: Refractive power and axial length had a significant relation to choroidal thickness measured by OCT. When excluding eyes with pathologic myopia, high myopia in healthy eyes may cause choroidal thinning.
|
|
KEYWORD
|
|
Axial length, Choroidal thickness, Optical coherence tomography, Refractive power
|
|
FullTexts / Linksout information
|
|
|
|