The Change of Multifocal Visual Evoked Potential in Unilateral Anisometropic Amblyopia before and after Occlusion Treatment
Jeon Ji-Hoon

Kyung Sung-Eun
Abstract
before and after occlusion treatment.

Methods: The mfVEP was performed using RETIscan¨Þ (Roland,Brandenburg, Germany) for patients with unilateral anisometropic amblyopia before and after occlusion treatment. Amplitude and latency values of mfVEP were analyzed according to the field divided by 6 rings or 4 sectors.

Results: The each amplitude of values of all 6 rings were not significantly different before treatment (p = 0.077) in amblyopic eyes. However, the value of ring 1 (p = 0.00) was significantly higher than the value of other rings after treatment. In fellow eyes, the values of ring 1 was consistently significantly higher than the value of other rings before (p = 0.014) and after (p = 0.049) occlusion treatment. Additionally, the amplitudes of ring 1 (p = 0.005) and ring 3 (p = 0.007) were significantly increased in amblyopic eyes after occlusion treatment. In fellow eyes, the values of all rings did not change significantly. The analysis of amplitudes with 4 sectors revealed no significant result. The analysis of latencies with 6 rings and 4 sectors revealed no significant result.

Conclusions: The change in amplitude on the central field (ring 1) in amblyopic eyes can be a useful objective monitoring method observing the improvement progress in visual acuity.
KEYWORD
Anisometropic amblyopia, Multifocal visual evoked potential, Occlusion treatment, Ring 1