Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0360220200610050550
Journal of the Korean Ophthalmological Society
2020 Volume.61 No. 5 p.550 ~ p.553
Accidental Swallowing of Nasal Packing Gauze during Silicone Tube Intubation under Local Anesthesia
Kong Jeong-Han

An Ye-Rim
Choi Youn-Joo
Abstract
Purpose: To report a case of accidental swallowing of nasal packing gauze during silicone tube intubation under local anesthesia.

Case summary: A 58-year-old male patient underwent silicone tube intubation for partial nasolacrimal duct obstruction on the right side. In preparing for surgery, six cottonoids soaked were packed in righ nasal cavity, to facilitate anesthesia and prevent bleeding. Strings detectable by X-ray were attached at the cottonoids and cut 5 cm from the nostrils. After surgical hand scrubbing, the strings were not present. One cottonoid was found in the nasal cavity, but five cottonoids could not be detected by endonasal endoscopic exploration. The patient said he swallowed ¡°something like sputum¡±. He did not notice any discomfort and the surgery was performed as scheduled. Abdominal X-ray performed immediately after surgery showed the presence of the five strings in the stomach. The strings were not seen on X-ray conducted 4 days later. The patient defecated normal stools three times and did not notice any discomfort over the course of 4 days.

Conclusions: Surgeons need to be aware of the possibility of accidental swallowing of nasal packing gauze during nasolacrimal duct surgery. Use of gauze detectable by X-ray is helpful to determine its location.
KEYWORD
Accidental swallowing, Cottonoid, Gauze packing,, Silicone tube intubation, X-ray detectable gauze
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø