KMID : 0360220230640080694
|
|
Journal of the Korean Ophthalmological Society 2023 Volume.64 No. 8 p.694 ~ p.699
|
|
Refractive Outcomes of Intraocular Lenses with Different Haptic Designs Following Phacovitrectomy with Gas Tamponade
|
|
Lee Soo-Yeon
Lee Jung-Min Lee Sung-Jin
|
|
Abstract
|
|
|
Purpose: To compare the refractive outcomes of closed C-loop and C-loop intraocular lenses (IOLs) following phacovitrectomy with gas tamponade.
Methods: Medical records of 42 patients (43 eyes) who underwent phacovitrectomy with gas tamponade for idiopathic macular holes between January 2021 and June 2022 were retrospectively reviewed. Closed C-loop (26 eyes; Eyelike K-flex Aspheric¢ç, Koryo Eyetech, Seoul, Korea) and C-loop (17 eyes; Tecnis¢ç ZCB00, Johnson & Johnson Vision, Santa Ana, CA, USA) IOLs were surgically implanted. The main outcome measures were postoperative prediction error and absolute error.
Results: There was no significant difference in mean absolute error at 5 months postoperatively (0.34 ¡¾ 0.24 diopters [D] and 0.30 ¡¾ 0.25 D in the closed C-loop and C-loop IOL groups, respectively; p = 0.502). The mean prediction error at 5 months postoperatively also showed no significant difference between the groups (-0.28 ¡¾ 0.30 D and -0.16 ¡¾ 0.36 D, respectively; p = 0.242). Myopic shift was observed in both groups.
Conclusions: There was no significant difference in refractive outcomes between closed C-loop IOLs and C-loop IOLs. A myopic shift was observed in both groups; this should be taken into consideration when calculating IOL power following phacovitrectomy with gas tamponade.
|
|
KEYWORD
|
|
C-loop intraocular lens, Closed C-loop intraocular lens, Gas tamponade, Phacovitrectomy
|
|
FullTexts / Linksout information
|
|
|
|