Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0361020010440010037
Korean Journal of Otolaryngology - Head and Neck Surgery
2001 Volume.44 No. 1 p.37 ~ p.40
Diagnostic Efficacy of High Resolution Computerized Tomography (HRCT) on Labyrinthine Fistula
Á¤ÇÏ¿ø/Hawon Jung
¹Ú¹ÎÇö/°­Á¦±¸/¼Ûº´È£/±¸ÀÚ¿ø/Á¤¼±¿À/±èÁ¾¼±/Min Hyun Park/Jae Goo Kang/Byeong Ho Song/Ja Won Koo/Sun O Chang/Chong Sun Kim
Abstract
Background and Objectives : The aim of the study was to evaluate the diagnostic efficacy of high resolution computed tomography (HRCT) of the labyrinthine fistulae on the temporal bone. Materials and Methods : 47 labyrinthine fistula cases that
had
undergone preoperative HRCT of the temporal bone were reviewed retrospectively. All the patients were proved to have labyrinthine fistulae during the operation for chronic otitis media with cholesteatoma from January 1983 through July 1999.
Results
:
Fistulae on the lateral semicircular canal were more effectively detected (78.6%) with conventional axial and coronal view than other site (21.4%). Detection rates of fistula were increased with decreased thickness of HRCT slices. Conclusion :
With
decreasing thickness of HRCT slices, the temporal bone CT's detection rate of labyrinthine fistulae were increased. For the fistulae on the superior and posterior semicircular canal, the efficacy of the temporal bone CT was limited.
KEYWORD
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø