Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0361420020260030337
Journal of Korean Academy of Rehabilitation Medicine
2002 Volume.26 No. 3 p.337 ~ p.341
Correlation between Doppler Ultrasonography and Impedance Plethysmography in Lower Extremity Varicose Vein




Abstract
Objective: To investigate the diagnostic validity of doppler ultrasonography (US) and impedance plethysmography (IPG) using photoplethysmography for evaluation of varicose vein of the lower extremities.

Method: One hundred sixty-six limbs in 83 consecutive patients with varicose vein were included. Venous reflux and deep venous lesions were assessed by doppler US. Venous filling time was evaluated using IPG. Diagnostic capabilities of two
methods were analyzed using Receiver Operating Characteristic (ROC) curve.

Results: Doppler US identified superficial venous reflux in sixty-nine of 119 limbs with varicose vein and no abnormalities in 34 of 47 normal limbs (sensitivity, 58%; specificity, 75%). IPG demonstrated superficial venous insufficiency in
75 of
the affected limbs and normal refill time in 38 of the normal limbs (sensitivity, 63%; specificity, 81%). Sensitivity was increased to 82% when both tests were used together. Area under the ROC curve was 0.66 in doppler US, 0.72 in IPG, and 0.76 in
both
tests. Deep venous lesion was found in 31 limbs using the both tests; 15 limbs with doppler US and 18 limbs with IPG.

Conclusion: IPG was more superior to doppler US in diagnosing venous insufficiency. The combination of both tests provided more accurate diagnostic information in assessing venous valvular function.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø