Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0361619960310010072
Journal of the Korean Orthopaedic Association
1996 Volume.31 No. 1 p.72 ~ p.81
Cementless Total Hip Arthroplasty Using Hydroxyapatite-Coated Femoral stem(Two-Year Clinical and Radiologic Follow-Up)



Abstract
Materials and Methods:
@EN From Jan. 1991 to Dec. 1992, we carried out 177 cases of Total Hip Arthroplasty using hydroxyapatite-coated implants of 167 patients, and among thses. 153 cases in 144 patients were followed up more than 24 months. The implants used were 74
cases of
Mallory-Head Hip system, 41 cases of Ominifit system and 38 cases of Profile system. Results: The average Harris Hip Score was 48.3 points preoperatively, 94 points at POD 1 year and 95.7 at POD 2 years. Seven patients(5.2%) complained thigh pain
at POD
2 years. On the radiologic findings, cancellous condensation was noted around the hydroxyapatite coating region of femoral stem in 84 cases(54.2%), and radiolucent lines were noted at the non-coating region of distal stem in 102 cases(67.7%), but
were
less than 2mm and not progressive.
There was no statistically significant differences among the groups of these three implants (P<0.05).
@ES Comments:
@EN This early result of femoral stems with hydroxyapatite-coating was quite satisfactory, however, long-term follow-up studies will be necessary.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø